1. Refrigerant Air Dryer
1) Normal inlet temperature Air-cooling Refrigerated Air Dryer Capacity (m3/min): 0.7, 1.2, 2.4, 3.8, 6.5, 8.5, 10, 13.8, 17, 23, 27, 33, 45, 55, 60
2) Normal inlet temperature Air-cooling Refrigerated Air Dryer Capacity (m3/min): 0.7, 1.2, 2.4, 3.8, 6.5, 8.5, 10.7, 13.5, 17, 23, 27, 33, 45, 55, 60
Working condition and Technical data
Inlet temperature Normal inlet Temperature≤45 centidegree High inlet Temperature≤80 centidegree Cooling method Air-cooling Ambient temperature ≤38 centidegree Design dew point 1.7 centidegree Refrigerant R-22 Inlet pressure 0.2-1.0MPa Pressure drop ≤0.02MPa
2. Purge Desiccant Air Dryer
Capacity(m3/min): 1.2, 2.4, 3.8, 6.5, 8.5, 11, 13.5, 17, 22, 27, 32, 42, 55, 65, 85, 110, 160, 210
Working condition and Technical data
Inlet temperature 0-45 centidegree Inlet oil content ≤0.01ppm Working pressure 0.6-1.0Mpa Dew point ≤-20 centidegree- -70 centidegree Purge air ≤12% Desiccant activated alumina & molecular sieve Purge mode heatless purge Working method continuing alternative working between two towers Working periods T=10-20min. Control mode micron computer auto controlling Installation mode indoor, non-basement
Working elements
Heatless Purge Desiccant Compressed Air Dryer using micro holes in the desiccant itself, adsorbing the moisture in the air because of capillary, desorbing it by pressure drop and adsorbing extra-heat. Currently, the equipment is making up of two towers, controlled by the Program Controller, the two towers working alternately, one is for adsorbing, the other is for desorbing, in this way continually circulating the work.
Product character
(1) Consistent outlet pressure dew points A. Rationalizing designed tower, ensure 4.8 second contact time, enough to dry saturated air at the dryer inlet to the desired dew point. B. 30% extra desiccant provide to compensate for natural bed aging, ensure top performance of desiccant bed. C. Large flow diffusers ensure even flow distribution through bed, eliminates channeling.
(2) Minimum purge air use, less than 12%, the lowest in the industry. A. Excellent designing tower, saves 95% of the heat of adsorption, stored heat maintains purge air temperature during regeneration, maximizing the purge air's ability to carry off moisture, minimizing the amount of purge air required. B. Drying and purging in counter flow arrangement, energy not wasted when wet air travels through dry desiccant. C. Ability to match purge air use to the demand on the dryer.
(3) Long desiccant life A. Suitable tower sized make the air velocity through the bed won't fluidize desiccant, making good use of the desiccant. B. Rationalizing system, remove oil and heavy contaminants before flow into the tower, protects bed from contamination.
(4) Using butterfly valve and reliable program controller which can be auto timing and auto switching, works stable and reliable, unaffected from electric net, pressure and electric field.
(5) Scientifically designed switch time ensuring the air pressure being stable, running without waving.
(6) Non basement, easy to install
|